top of page
TTA-79-NN-CC Top Tower Amplifier
SKU TTA-79-NN-CC
TTA-79-NN-CC
TTA-79-NN-CC
TTA-User-Manual
Download Product Specs
Top-Tower Amplifier Our modular Tower-Top Amplifier (TTA) systems provide superior receiver system performance and excellent electrical reliability by improving base station Up Link (UL) sensitivity. TTA systems overcome link budget imbalance between the Up Link and Down Link (DL) by boosting received signal to overcome received path loss (feeder losses).
- Improved base station UL sensitivity
- Redundant LNA with automatic change over
- LNA bypass modes
- Monitoring & Control via GUI
- SNMP Alarms
- Remote Access
Description
Top-Tower Amplifier Our modular Tower-Top Amplifier (TTA) systems provide superior receiver system performance and excellent electrical reliability by improving base station Up Link (UL) sensitivity. TTA systems overcome link budget imbalance between the Up Link and Down Link (DL) by boosting received signal to overcome received path loss (feeder losses).
- Improved base station UL sensitivity
- Redundant LNA with automatic change over
- LNA bypass modes
- Monitoring & Control via GUI
- SNMP Alarms
- Remote Access
Additional information
TOWER SECTION | SPECIFICATIONS |
---|---|
Frequency Range, MHz | 794-824 |
Bandwidth, MHz | 30 |
Typical Gain, dB | 29 |
3rd Order Intercept, dBm | 14.3 |
Return Loss, all ports, dB | '-20 |
Surge protection, all ports, µS | IEC 61000-4-5 5 strikes 26 KA 8/20 µS 10 strikes 20 KA 8/20 µS 10 strikes 3 kA 10/35 µS slow pulse waveform |
Integrated Test port, dB | 30 dB coupling |
Connectors | N- Female |
Power, VDC | 48 |
Finish | Stainless steel |
BASE UNIT | SPECIFICATIONS |
No. of RX Output Ports | 8\, 16\, 32 |
Gain Min./Typical, dB | Control and distribution unit = -5 |
Noise Figure, dB | 2.9 |
IIP3, dB | 33 |
RF Port Return Loss, dB | '-22 |
Size (H x W x L) in | 2 x 10 1/2 x 19 |
Finish, Front | Black |
RX Output Connectors | BNC- Female |
TX Connector Type | N- Female |
Power Input, Standard | 110/220 VAC 50/60Hz\, 12W |
Weight, lbs | 8 |
Mounting | EIA Standard 19” 1 RU |
Temperature Range, °C | '-0° to +50° |
Ordering Information
Contact sales@comprodcom.com for information.